Abstract:   (5714 Views)

Background and Objectives: Streptococcus pneumoniae accounts for bacterial meningitis and is an important cause of morbidity among children and elderly. Control of this disease depends on rapid detection of the causative bacteria. The methods for detection of Streptococcus pneumoniae are gram staining, culture, and serological tests. These tests are time consuming and are limited by antimicrobial agents leading to false negative results. Currently, molecular methods such as PCR are used routinely for detection of infectious organisms. This study was performed with the aim of designing an improved PCR assay for the detection of Streptococcus pneumoniae.

Methods: The specific diagnostic primers were designed based on ply gene of the bacterium. After amplifying the target gene on the genomic DNA, the PCR product was cloned in pTZ57R/T plasmid and the confirmed pTZ-ply plasmid was used as positive control in next experiments. Sensitivity of the assay was determined by performing the PCR on 10-fold serial dilutions of pTZ-ply. Specificity of the assay was determined using the genomic DNA of other related or unrelated bacterial species.

Results: The PCR, as expected, generated a 727bp amplicon. No PCR amplification was observed on the genome of negative controls. These findings indicate high specificity of the PCR. The lowest limit of detection of the assay in the detection of the ply gene was 250 copies in a 25µl reaction.

Conclusion: The high sensitivity, specificity, and rapidity of the designed assay suggested the assay as an appropriate test for use in clinical laboratories. The further evaluation of the assay using clinical samples or artificially contaminated materials will confirm the application of this assay in clinical setti

Full-Text [PDF 302 kb]   (2130 Downloads)    
Type of Study: Original Article |
Received: 2016/04/6 | Accepted: 2016/04/6 | Published: 2016/04/6

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2025 CC BY-NC 4.0 | Qom University of Medical Sciences Journal

Designed & Developed by : Yektaweb